Files
dingtalk-workspace-cli/docs/connect-daemon-service.md

149 lines
5.0 KiB
Markdown

# Running the connector as a 7x24 service
`dws dev connect` keeps a DingTalk robot wired to a local agent over a
Stream long-connection. By default it runs in the foreground and dies when the
terminal closes. For an unattended "digital employee" you have two options.
> **Security**: prefer `--unified-app-id <uappid>` over
> `--robot-client-id/--robot-client-secret`. With `--unified-app-id` the CLI
> resolves clientId/clientSecret at runtime through `dev app credentials get`,
> so the secret never appears in `ps` / journald / shell history. Pasting
> `--robot-client-secret` onto argv lets any local user read your AppSecret
> with `ps -ef`; the CLI will warn you when you do that.
## Option A: built-in daemon (recommended for a quick start)
```bash
# Detach into a background supervisor that restarts the connector if it crashes.
dws dev connect --daemon \
--channel claudecode \
--unified-app-id <unifiedAppId>
# Inspect / stop / restart it (locate the daemon by unifiedAppId).
dws dev connect status --unified-app-id <unifiedAppId>
dws dev connect stop --unified-app-id <unifiedAppId>
dws dev connect restart --unified-app-id <unifiedAppId>
```
- The parent prints the daemon pid and the log path, then exits.
- A supervisor process (POSIX `setsid`, detached from the terminal) keeps a
worker connector alive, restarting it with exponential backoff (1s..60s, up to
10 consecutive fast failures) when it exits abnormally.
- The single-instance lock (one connector per robot per machine) is reused, so a
duplicate daemon refuses to start.
- Logs go to `~/.dws/connect/<key>/daemon.log` with size-based rotation
(5 MB x 2 backups), and the pid file lives at
`~/.dws/connect/<key>/daemon.pid`.
- The daemon does NOT survive a reboot. For that, use Option B.
> Windows: `--daemon` is not supported (no `setsid` / POSIX signal stop). Use a
> Windows service wrapper around the foreground command instead.
## Option B: OS service manager (survives reboot)
Use the foreground command (NOT `--daemon`) and let the OS supervise and
restart it. This is the most robust way to get boot-time auto-start.
### macOS — launchd
Save as `~/Library/LaunchAgents/com.dingtalk.dws.connect.plist`, edit the paths
and `REPLACE_UNIFIED_APP_ID`, then `launchctl load -w <path>`.
```xml
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE plist PUBLIC "-//Apple//DTD PLIST 1.0//EN"
"http://www.apple.com/DTDs/PropertyList-1.0.dtd">
<plist version="1.0">
<dict>
<key>Label</key>
<string>com.dingtalk.dws.connect</string>
<key>ProgramArguments</key>
<array>
<string>/usr/local/bin/dws</string>
<string>dev</string>
<string>connect</string>
<string>--channel</string>
<string>claudecode</string>
<string>--unified-app-id</string>
<string>REPLACE_UNIFIED_APP_ID</string>
</array>
<key>RunAtLoad</key>
<true/>
<key>KeepAlive</key>
<true/>
<key>ThrottleInterval</key>
<integer>10</integer>
<key>StandardOutPath</key>
<string>/tmp/dws-connect.out.log</string>
<key>StandardErrorPath</key>
<string>/tmp/dws-connect.err.log</string>
<key>EnvironmentVariables</key>
<dict>
<key>PATH</key>
<string>/usr/local/bin:/usr/bin:/bin</string>
</dict>
</dict>
</plist>
```
`KeepAlive=true` makes launchd restart the connector if it exits; the connector
itself relies on the single-instance lock to avoid duplicates.
### Linux — systemd (user service)
Save as `~/.config/systemd/user/dws-connect.service`, edit paths and
`REPLACE_UNIFIED_APP_ID`, then:
```bash
systemctl --user daemon-reload
systemctl --user enable --now dws-connect.service
# allow it to keep running after logout:
loginctl enable-linger "$USER"
```
```ini
[Unit]
Description=DWS DingTalk robot connector
After=network-online.target
Wants=network-online.target
[Service]
Type=simple
ExecStart=/usr/local/bin/dws dev connect \
--channel claudecode \
--unified-app-id REPLACE_UNIFIED_APP_ID
Restart=always
RestartSec=5
# Optional hardening:
# NoNewPrivileges=true
# PrivateTmp=true
[Install]
WantedBy=default.target
```
`Restart=always` + `RestartSec` gives crash recovery; systemd captures stdout/
stderr into the journal (`journalctl --user -u dws-connect -f`).
## Legacy: passing clientId/clientSecret directly (not recommended)
If you truly must pass credentials on the command line (e.g. one-off local
debugging without a unifiedAppId), the CLI still accepts
`--robot-client-id <id> --robot-client-secret <secret>` and will print a
security warning to stderr. This form:
- exposes `clientSecret` to every user on the box via `ps -ef`;
- gets baked into launchd `ProgramArguments` / systemd `ExecStart`, which
makes rotation harder;
- means `dws dev connect restart` cannot re-fetch credentials — you
must re-run the full command yourself.
Prefer `--unified-app-id`. Only fall back to the pair when you understand the
trade-off.
## Which to choose
- Just need it to outlive the terminal and self-heal on crash → `--daemon`.
- Need it to come back after a reboot, with the OS owning the lifecycle → use
launchd / systemd with the foreground command.